The mapping list

The mapping list is the interface specification for one printer. The integrator creates it with Mapping list for PLC… in the Modbus settings (see Printer setup) and hands it to the PLC programmer. It is always in English.

The list has a header and two tables, one for coils and one for registers.

FieldDescription
AuroraThe printer's software version.
ExportedWhen the list was created.
Modbus TCPPort and unit identifier, see Connection.
AddressesReminder of the two address notations, see Addressing.

If the list was exported with unsaved changes in the settings, it says so. Those changes are not active on the printer until they are saved.

Coil table​

ColumnDescription
Addr0-based protocol address.
Ref1-based Modicon reference, 0xxxx.
AccessR read-only, RW read/write, W write (auto-clear action, always reads 0).
TargetThe signal or action the coil is bound to.
NotesFor action coils, how the action is triggered.

Register table​

ColumnDescription
Addr0-based protocol address range of the item.
Ref1-based Modicon reference range, 4xxxx.
RegsNumber of registers the item occupies.
TypeData type, see Data types.
AccessR read-only, RW read/write, W write-only (reads 0).
TargetWhat the item is bound to, see Registers.
NotesDetails, such as the unit, or what a write does.

Example​

This is the example mapping list used throughout this documentation. It is for a printer with the ID NoLabel.

Aurora Modbus TCP mapping list

Aurora: 5.4.1
Exported: 2026-09-25 10:00
Modbus TCP: port 502, unit id ignored
Addresses: Addr = 0-based protocol address; Ref = Modicon 1-based reference (0xxxx coils, 4xxxx registers)

Protocol rules, data encoding and the meaning of each target type are described in the Aurora Modbus TCP Interface document.

Coils / discrete inputs
Read with FC 01 or 02, write with FC 05 or 15. Unmapped coils read 0. An action coil is a command bit: see section 5 of the interface document.

Addr Ref Access Target Notes
---- ----- ------ ------------------------------ -----------------------------------------
0 00001 R printer.NoLabel.ready
1 00002 R printer.NoLabel.printing
2 00003 R printer.NoLabel.label_selected
3 00004 R printer.NoLabel.red
4 00005 R printer.NoLabel.ink_low
8 00009 RW plc.line_running
16 00017 RW printer.NoLabel.start_request action; runs on 0 to 1, write 0 to re-arm
17 00018 RW printer.NoLabel.stop_request action; runs on 0 to 1, write 0 to re-arm
18 00019 W printer.NoLabel.abort_print action; every write of 1 runs it, reads 0

Holding / input registers
Read with FC 03 or 04, write with FC 06 or 16. A read must cover whole items; unmapped or partial reads return exception 02. 32-bit values are high word first; STRING is 2 bytes per register, first byte in the high byte.

Addr Ref Regs Type Access Target Notes
----- ----------- ---- ------ ------ ----------------------------------------- -------------------------------------------------------------------------------------------------------
0-1 40001-40002 2 UINT32 RW Counter: Serial write sets the counter
2-9 40003-40010 8 STRING RW Variable: Lot text
10 40011 1 UINT16 RW Fixed speed: NoLabel mm/s
11-12 40012-40013 2 UINT32 R Statistic: printer.NoLabel.labels.printed value since last reset
13-19 40014-40020 7 BLOCK R Reserved reads 0
20-35 40021-40036 16 STRING W Select label: NoLabel write-only, reads 0; each write selects label "<value>"
36-43 40037-40044 8 STRING W Select from table: NoLabel write-only, reads 0; each write looks up "<value>" in table "Products", column "Article"; job is queued
100 40101 1 UINT16 RW Internal: plc_request storage register shared with Aurora software
101 40102 1 UINT16 R Internal: aurora_reply storage register shared with Aurora software

What the example provides:

  • Coils 0–4 report the printer's status. Coil 8 is a user signal that the PLC sets to tell the printer that the line is running.
  • Coils 16 and 17 start and stop the ink system; the PLC must write 0 before it can run the same action again. Coil 18 aborts the current print on every write of 1.
  • Registers 0–12 hold a serial number counter, a lot number variable, the line speed and the number of printed labels. The reserved block at 13–19 lets the PLC read 0–35 in one request.
  • Registers 20–35 select a label by name, and 36–43 select a product from the table Products.
  • Registers 100 and 101 are a request and reply pair for exchanging data with an extension.

The Cookbook shows how to use each of these.